FACADES MAINTENANCE SYSTEM
Trejor anchor system for Facade Maintenance was designed to atend the decree 157 from 01/10/06, which changed the editorial of NR 18, including, among others, item 18.15.6, which require the installation of anchorage points that support a punctual load of 1.200 Kgf to sustain scaffolds and safety ropes.
-
TSF Inox Anchor:
-
Threaded Lifting Clutch - TI
-
Plastic Screw Finishing - TAP
-
Golden Form Washer
-
Conic Socket
-
Screw
Stainless steel anchor with craved bar to ensure it's perfect anchorage in the concrete structure;
Reusable tool connected to the TSF Inox Anchor during the maintenance facade.
Reusable element developed to protect the anchor thread when the anchor is not being used.
External compensation washer to fix TSF Inox Anchor in the wooden form.
Conic socket for positioning the TSF Inox Anchor at the building structure.
Screw to fix the anchor in the wooden form, ensuring that it remains perpendicular at the concrete surface.
IInstruction:
M-16 Hexagonal Screw
Nail
M-16 Hexagonal Screw
Wooden Frame
Wooden Frame
Anchoring
Concrete
Compensating Frame Washer
Wooden Frame
Anchoring
Anchoring
Concrete
Removal of the hexagonal M 16 screw
M-16 Hexagonal Screw
Wooden Frame
Conic plug
Finishing
Finishing
M-16 Hexagonal Screw
Removal of the frame
Finishing done, removal of the M16 screw and the conic plug
Finishing must cover only the Conic Plug, leaving the head of the M16 screw on the outside.
Accessories properly screwed into the insert for the application of the finishing.
Concrete
Anchoring
Anchoring
Concrete
Concrete
Conic plug
Finishing
M-16 Hexagonal Screw
Empty space created by the Conic Plug for the installation of the TI16
Accessories are placed on the insert before the application of the finishing
Finishing
TI16 installed and ready for use.
The TSF insert must have 2.5 cm on the outside of the element.
The system for the Facade Maintenance consider 4 cm of finishing over the concrete structure. In cases where the finishing is different, it’s necessary to prevent the usage of one of the following pieces:
Adapter Washer TI16
Adapter Washer on demand welded on TI16
Weld
For a finishing higher than 4 cm, it must be used the internal compensation socket at the concreting moment to adjust the TSF Inox Anchor ensuring that it’s 1,5 cm far from the building finishing. The compensation socket will be produced accordingly with the necessity.
Conic Plug
Anchoring
Concrete
Internal Compensation Plug
M16
Hexagonal Screw
Demonstration: